Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Dent Mater J ; 43(1): 112-118, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38072411

RESUMEN

This study evaluated the influence of different translucent resins (Z350 and Opallis) for customizing fiber posts and light-curing the cementation system using different LED equipment (V, Valo or R, Radii-Cal) on the bond strength and adhesive failure pattern at 24 h and 6 months. Eighty roots were prepared and divided into 4 groups (n=20): ZV (Z350 resin and LED Valo), ZR (Z350 resin and LED Radii-Cal), OV (Opallis resin and LED Valo), OR (Opallis resin and LED Radii-Cal). After post space preparation, the fiber post was customized and cemented with self-adhesive cement and light-curing using V or R LED equipment. Bond strength values were submitted to 2-way ANOVA test. ZV and ZR showed higher bond strength values than the other groups at 6 months of evaluation (p<0.05). The Z350 resin has a favorable influence on the bond strength of self-adhesive cement to root dentin, regardless of the LED polymerization equipment used.


Asunto(s)
Recubrimiento Dental Adhesivo , Técnica de Perno Muñón , Resinas Compuestas/química , Cementación , Cementos de Resina/química , Dentina , Ensayo de Materiales , Vidrio/química
2.
Braz Dent J ; 34(4): 115-126, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37909634

RESUMEN

This study was aimed at analyzing the surface properties of a universal resin composite and evaluating the effect of preheating on its physicochemical properties. Two commercial resin composites were used under two conditions: Filtek Universal Restorative (UR); UR preheated (URH); Filtek Supreme (FS) and FS preheated (FSH). The film thickness (FT) test (n = 10) was done using two glass slabs under compression. Flexural strength (FLS) and modulus (FLM) were evaluated using a three-point flexion test (n = 10). Polymerization shrinkage stress (PSS) was evaluated in a universal testing machine (n = 5). Gap width (GW) between composite and mold was measured in internally polished metallic molds (n = 10). The degree of conversion (DC) was evaluated by Fourier Transform Infrared spectroscopy (n = 3). The morphology of the filler particles was checked by scanning electron microscope (SEM) and EDX analysis. Surface gloss (SG) and surface roughness (SR) were evaluated before and after mechanical brushing (n = 10). The outcomes were submitted to 2-way ANOVA and Tukey's test (α = 0.05). Lower mean values of FT were observed for the preheated groups when compared to the non-preheated groups. URH and FSH showed higher mean values of FLS and FLM when compared with UR and FS. No differences were observed between groups in the PSS test. The GW was higher for the UR and FS groups when compared with URH and FSH. The DC was higher for preheated resin composites when compared to the non-preheated groups. The SR of the UR composite was higher than the FS after mechanical brushing, while the SG was higher for the FS groups. In conclusion, the universal resin composite tested generally presented similar physicochemical properties compared with the nanofilled resin composite and either similar or slightly inferior surface properties. The preheating improved or maintained all properties evaluated.


Asunto(s)
Resinas Compuestas , Resistencia Flexional , Ensayo de Materiales , Resinas Compuestas/química , Propiedades de Superficie , Hormona Folículo Estimulante
3.
Braz Dent J ; 34(4): 62-71, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37909643

RESUMEN

This study aimed to evaluate the effect of antioxidant solutions on fracture strength and bonding performance in non-vital and bleached (38% hydrogen peroxide) teeth. One hundred and eighty dentin specimens were obtained, 60 for each test: fracture strength, hybrid layer thickness, and bond strength. The groups (n=10) were randomly composed according to post-bleaching protocol: REST - restoration, without bleaching; BL - bleaching + restoration; SA - bleaching, 10% sodium ascorbate solution, and restoration; AT - bleaching, 10% α-tocopherol solution, and restoration; CRAN - bleaching, 5% cranberry solution, and restoration; CAP - bleaching, 0.0025% capsaicin solution, and restoration. Data were analyzed with ANOVA, Kruskal-Wallis, Dunn, and Qui-Square tests (α=0.05). The highest fracture strength values were observed in REST (1508.96 ±148.15 N), without significant difference for the bleached groups (p>0.05), regardless of the antioxidant use. The hybrid layer thickness in the group that was not subjected to bleaching (REST) was significantly higher than in any other group. The bond strength in the bleached and antioxidants-treated groups (SA, AT, CRAN, CAP) has no differences with the bleached group without antioxidants (BL). Adhesive failures were predominant in the groups that did not receive the antioxidant application. In conclusion, the evaluated antioxidants did not show an effect on the fracture strength, hybrid layer thickness, or bond strength of dentin bleached after endodontic treatment. The application of 10% sodium ascorbate, 10% alpha-tocopherol, 5% cranberry, or 0.0025% capsaicin solutions is not an effective step and should not be considered for the restorative protocols after non-vital bleaching.


Asunto(s)
Recubrimiento Dental Adhesivo , Blanqueamiento de Dientes , Antioxidantes/análisis , Antioxidantes/química , Antioxidantes/farmacología , alfa-Tocoferol/análisis , alfa-Tocoferol/farmacología , Capsaicina/análisis , Capsaicina/farmacología , Dentina/química , Ácido Ascórbico/análisis , Ácido Ascórbico/química , Ácido Ascórbico/farmacología , Blanqueamiento de Dientes/métodos
4.
Braz. dent. j ; 34(4): 62-71, July-Aug. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1520328

RESUMEN

Abstract This study aimed to evaluate the effect of antioxidant solutions on fracture strength and bonding performance in non-vital and bleached (38% hydrogen peroxide) teeth. One hundred and eighty dentin specimens were obtained, 60 for each test: fracture strength, hybrid layer thickness, and bond strength. The groups (n=10) were randomly composed according to post-bleaching protocol: REST - restoration, without bleaching; BL - bleaching + restoration; SA - bleaching, 10% sodium ascorbate solution, and restoration; AT - bleaching, 10% α-tocopherol solution, and restoration; CRAN - bleaching, 5% cranberry solution, and restoration; CAP - bleaching, 0.0025% capsaicin solution, and restoration. Data were analyzed with ANOVA, Kruskal-Wallis, Dunn, and Qui-Square tests (α=0.05). The highest fracture strength values were observed in REST (1508.96 ±148.15 N), without significant difference for the bleached groups (p>0.05), regardless of the antioxidant use. The hybrid layer thickness in the group that was not subjected to bleaching (REST) was significantly higher than in any other group. The bond strength in the bleached and antioxidants-treated groups (SA, AT, CRAN, CAP) has no differences with the bleached group without antioxidants (BL). Adhesive failures were predominant in the groups that did not receive the antioxidant application. In conclusion, the evaluated antioxidants did not show an effect on the fracture strength, hybrid layer thickness, or bond strength of dentin bleached after endodontic treatment. The application of 10% sodium ascorbate, 10% alpha-tocopherol, 5% cranberry, or 0.0025% capsaicin solutions is not an effective step and should not be considered for the restorative protocols after non-vital bleaching.


Resumo Este estudo teve como objetivo avaliar o efeito de soluções antioxidantes na resistência à fratura e resistência de união em dentes tratados endodonticamente e clareados (38% de peróxido de hidrogênio). Cento e oitenta espécimes de dentina foram obtidos, 60 para cada teste: resistência à fratura, espessura da camada híbrida e resistência de união. Os grupos (n=10) foram compostos aleatoriamente de acordo com o protocolo pós-clareamento: REST - restauração, sem clareamento; BL - clareamento + restauração; SA - clareamento, solução de ascorbato de sódio a 10% e restauração; AT - clareamento, solução de α-tocoferol a 10% e restauração; CRAN - clareamento, solução de cranberry a 5% e restauração; CAP - clareamento, solução de capsaicina 0,0025% e restauração. Os dados foram analisados ​​com os testes ANOVA, Kruskal-Wallis, Dunn e Qui-Quadrado (α=0,05). Os maiores valores de resistência à fratura foram observados em REST (1508,96 ±148,15 N), sem diferença significativa para os grupos clareados (p>0,05), independente do uso de antioxidantes. A espessura da camada híbrida no grupo que não foi submetido ao clareamento (REST) foi significativamente maior do que em qualquer outro grupo. A resistência de união nos grupos clareado e tratado com antioxidantes (SA, AT, CRAN, CAP) não apresentou diferenças com o grupo branqueado sem antioxidantes (BL). As falhas adesivas foram predominantes nos grupos que não receberam a aplicação do antioxidante. Em conclusão, os antioxidantes avaliados não mostraram efeito sobre a resistência à fratura, espessura da camada híbrida ou resistência de união à dentina clareada após tratamento endodôntico. A aplicação de soluções de ascorbato de sódio 10%, alfa-tocoferol 10%, cranberry 5% ou capsaicina 0,0025% não é uma etapa eficaz e não deve ser considerada para os protocolos restauradores após clareamento não vital.

5.
Braz. dent. j ; 34(4): 115-126, July-Aug. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1520337

RESUMEN

Abstract This study was aimed at analyzing the surface properties of a universal resin composite and evaluating the effect of preheating on its physicochemical properties. Two commercial resin composites were used under two conditions: Filtek Universal Restorative (UR); UR preheated (URH); Filtek Supreme (FS) and FS preheated (FSH). The film thickness (FT) test (n = 10) was done using two glass slabs under compression. Flexural strength (FLS) and modulus (FLM) were evaluated using a three-point flexion test (n = 10). Polymerization shrinkage stress (PSS) was evaluated in a universal testing machine (n = 5). Gap width (GW) between composite and mold was measured in internally polished metallic molds (n = 10). The degree of conversion (DC) was evaluated by Fourier Transform Infrared spectroscopy (n = 3). The morphology of the filler particles was checked by scanning electron microscope (SEM) and EDX analysis. Surface gloss (SG) and surface roughness (SR) were evaluated before and after mechanical brushing (n = 10). The outcomes were submitted to 2-way ANOVA and Tukey's test (α = 0.05). Lower mean values of FT were observed for the preheated groups when compared to the non-preheated groups. URH and FSH showed higher mean values of FLS and FLM when compared with UR and FS. No differences were observed between groups in the PSS test. The GW was higher for the UR and FS groups when compared with URH and FSH. The DC was higher for preheated resin composites when compared to the non-preheated groups. The SR of the UR composite was higher than the FS after mechanical brushing, while the SG was higher for the FS groups. In conclusion, the universal resin composite tested generally presented similar physicochemical properties compared with the nanofilled resin composite and either similar or slightly inferior surface properties. The preheating improved or maintained all properties evaluated.


Resumo Neste estudo avaliou-se propriedades físico-químicas e de superfície de um compósito universal pré-aquecido e comparado a um compósito convencional. Foram utilizados dois compósitos comerciais: Filtek Universal Restorative (UR); UR pré-aquecido (URH); Filtek Supreme (FS) e FS pré-aquecido (FSH). O teste de espessura de película (EP) (n = 10) foi feito usando duas placas de vidro sob compressão. A resistência à flexão (RF) e o módulo flexural (MF) foram avaliados por meio do teste de flexão de três pontos (n = 10). A tensão de contração de polimerização (TCP) foi avaliada em uma máquina de teste universal (n = 8). A largura da fenda (LF) entre o compósito e o molde foi medida em moldes metálicos polidos internamente (n = 10). O grau de conversão (GC) foi avaliado por espectroscopia de infravermelho com transformada de Fourier (n = 3). A morfologia das partículas de carga foi observada em microscopia eletrônica de varredura (MEV) e sua composição em EDX. Brilho superficial (BS) e rugosidade superficial (RS) foram avaliados antes e após escovação mecânica (n=10). Os resultados foram submetidos à ANOVA 2-fatores e as médias comparadas pelo teste de Tukey (α = 0,05). Menores valores médios de EP foram observados para os grupos pré-aquecidos quando comparados aos grupos não pré-aquecidos. URH e FSH apresentaram maiores valores médios de RF e MF quando comparados com UR e FS. Não foram observadas diferenças entre os grupos no teste TCP. A LF foi maior para os grupos UR e FS quando comparados com URH e FSH. O GC foi maior para os compósitos pré-aquecidos quando comparados aos não pré-aquecidos. A RS do compósito UR foi maior que o FS após a escovação mecânica, enquanto o BS foi maior para os grupos FS. Em conclusão, o compósito universal testado geralmente apresentou propriedades físico-químicas semelhantes em comparação ao compósito nanoparticulado e propriedades de superfície semelhantes ou ligeiramente inferiores. O pré-aquecimento melhorou ou manteve todas as propriedades avaliadas.

6.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1405312

RESUMEN

ABSTRACT: The objective of this in vitro study was to evaluate the effects of finishing protocols and oral hygiene procedures on the surface and mechanical properties of CAD/CAM ceramics. Specimens (n = 96, (15x10x2mm) of the leucite glass-ceramic (LGC) and feldspathic ceramic (FP) received mechanical polishing or glazing. Surface roughness (Ra) and microhardness (VHN) were obtained with a profilometer and a hardness tester, respectively, before and after each oral hygiene procedure (TB: toothbrushing; PB: prophylaxis with paste and rubber cup; and BJ: prophylaxis with bicarbonate jet). ANOVA, paired t and Tukey's tests were applied (a=0.05). For both materials, only BJ affected Ra's values when mechanical polishing was performed. Moreover, no significant variations in VHN were observed only for LGC glazed with TB. Significant Ra and VHN changes in both materials were observed with BJ. Besides, BJ exhibited similar effects to TB on VHN, regardless of the material and finishing protocol used. Changes in mechanical and surface properties varied with the finishing protocol and the oral hygiene method. In general, prophylaxis with bicarbonate jet was the most harmful method for both materials and the type of finishing protocol did not have a protective effect against changes produced by oral hygiene methods.


RESUMEN: El objetivo de este estudio in vitro fue evaluar los efectos de los protocolos de acabado y los procedimientos de higiene oral sobre la superficie y las propiedades mecánicas de las cerámicas CAD/CAM. Los especímenes (n = 96, (15x10x2mm) de vitrocerámica de leucita (LGC) y cerámica feldespática (FP) recibieron pulido mecánico o glaseado. La rugosidad de la superficie (Ra) y la microdureza (VHN) se obtuvieron con un perfilómetro y un probador de dureza, respectivamente, antes y después de cada procedimiento de higiene oral (TB: cepillado dental; PB: profilaxis con pasta y vaso de hule; y BJ: profilaxis con chorro de bicarbonato). Se aplicaron ANOVA, t pareada y prueba de Tukey (a=0.05). Para ambos materiales, solo BJ afectó los valores de Ra cuando se realizó el pulido mecánico. Además, no se observaron variaciones significativas en VHN solo para LGC vidriado con TB. Se observaron cambios significativos de Ra y VHN en ambos materiales con BJ. Además, BJ exhibió efectos similares a TB en VHN, independientemente del material y protocolo de acabado utilizado Los cambios en las propiedades mecánicas y superficiales variaron con el protocolo de acabado y el método de higiene oral. En general, la profilaxis con chorro de bicarbonato fue el método más perjudicial, tanto los materiales como el tipo de protocolo de acabado no tuvieron un efecto protector frente a los cambios producidos por los métodos de higiene oral.

7.
Braz Dent J ; 33(1): 68-76, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35262555

RESUMEN

This in vitro study evaluated the anti-erosive effect of an experimental varnish containing 5% stannous chloride (SnCl2) associated with different concentrations of NaF (NaF-free, 2.5% NaF, or 5.2% NaF) on bovine enamel and root dentin. One hundred samples were pre-eroded (0.3% citric acid, pH 2.6, 10 min) and randomized into five groups (n=10 for each substrate): Negative control - milli-Q water; NaF-free - Experimental varnish SnCl2-free and NaF-free; 2.5 NaF - Experimental varnish 5% SnCl2 associated with 2.5% NaF; 5.2 NaF: Experimental varnish 5% SnCl2 associated with 5.2% NaF and positive control - Commercial varnish containing 5% NaF (Duraphat). After the varnishes were applied, the erosive and abrasive challenges were carried out for five days. Loss of tooth structure (TSL) was determined by optical profilometry, and the loss of calcium (ΔCa2+) using atomic absorption spectroscopy. Dentin analysis was also performed by SEM. A one-way ANOVA/Bonferroni test was performed to analyze the data (α=0.05). The experimental 2.5 NaF and 5.2 NaF groups showed greater effectiveness in preventing TSL when compared to the other groups (p <0.05), regardless of the substrate. In addition, these groups showed lower loss in Ca2+ content when compared to the other groups (p <0.05), for enamel and dentin. Dentin showed greater TSL and ΔCa2+ loss when compared to enamel in all treatments (p <0.05). The 5.2% and 2.5% NaF-containing experimental varnishes showed promising results in both, the prevention of TSL and the loss of Ca2+, regardless of the substrate studied.


Asunto(s)
Erosión de los Dientes , Animales , Bovinos , Esmalte Dental , Fluoruros/farmacología , Fluoruros Tópicos/farmacología , Fluoruro de Sodio/farmacología , Compuestos de Estaño/farmacología , Erosión de los Dientes/prevención & control , Raíz del Diente
8.
Braz. dent. j ; 33(1): 68-76, jan.-fev. 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1364479

RESUMEN

Abstract This in vitro study evaluated the anti-erosive effect of an experimental varnish containing 5% stannous chloride (SnCl₂) associated with different concentrations of NaF (NaF-free, 2.5% NaF, or 5.2% NaF) on bovine enamel and root dentin. One hundred samples were pre-eroded (0.3% citric acid, pH 2.6, 10 min) and randomized into five groups (n=10 for each substrate): Negative control - milli-Q water; NaF-free - Experimental varnish SnCl₂-free and NaF-free; 2.5 NaF - Experimental varnish 5% SnCl₂ associated with 2.5% NaF; 5.2 NaF: Experimental varnish 5% SnCl₂ associated with 5.2% NaF and positive control - Commercial varnish containing 5% NaF (Duraphat). After the varnishes were applied, the erosive and abrasive challenges were carried out for five days. Loss of tooth structure (TSL) was determined by optical profilometry, and the loss of calcium (ΔCa2+) using atomic absorption spectroscopy. Dentin analysis was also performed by SEM. A one-way ANOVA/Bonferroni test was performed to analyze the data (α=0.05). The experimental 2.5 NaF and 5.2 NaF groups showed greater effectiveness in preventing TSL when compared to the other groups (p <0.05), regardless of the substrate. In addition, these groups showed lower loss in Ca2+ content when compared to the other groups (p <0.05), for enamel and dentin. Dentin showed greater TSL and ΔCa2+ loss when compared to enamel in all treatments (p <0.05). The 5.2% and 2.5% NaF-containing experimental varnishes showed promising results in both, the prevention of TSL and the loss of Ca2+, regardless of the substrate studied.


Resumo Este estudo in vitro avaliou o efeito anti-erosivo de um verniz experimental contendo 5% de cloreto estanoso (SnCl₂) associado a diferentes concentrações de NaF (sem NaF, 2,5% NaF ou 5,2% NaF) sobre esmalte e dentina radicular bovinos. Cem amostras foram pré-erodidas (ácido cítrico 0,3%, pH 2,6, 10 min) e randomizadas em cinco grupos (n=10 para cada substrato): Controle negativo - água milli-Q; Sem NaF - Verniz experimental sem SnCl2 e sem NaF; 2,5 NaF - Verniz experimental 5% SnCl2 associado a 2,5% NaF; 5,2 NaF: Verniz experimental 5% SnCl2 associado a 5,2% NaF e controle positivo - Verniz comercial contendo 5% NaF (Duraphat). Após a aplicação dos vernizes, os desafios erosivos e abrasivos foram realizados por cinco dias. A perda de estrutura dentária (PED) foi determinada por perfilometria óptica e a perda de cálcio (ΔCa2+) por espectroscopia de absorção atômica. A análise da dentina também foi realizada por MEV. Um teste ANOVA/Bonferroni de uma via foi realizado para analisar os dados (α=0,05). Os grupos experimentais 2,5 NaF e 5,2 NaF apresentaram maior eficácia na prevenção de PED quando comparados aos demais grupos (p<0,05), independentemente do substrato. Além disso, esses grupos apresentaram menor perda no teor de Ca2+ quando comparados aos demais grupos (p<0,05), para esmalte e dentina. A dentina apresentou maior PED e de ΔCa2+ quando comparada ao esmalte em todos os tratamentos (p<0,05). Os vernizes experimentais contendo NaF 5,2% e 2,5% apresentaram resultados promissores tanto na prevenção de PED quanto na perda de Ca2+, independente do substrato estudado.

9.
Braz Oral Res ; 35: e084, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34431849

RESUMEN

The objective of this work was to evaluate the relationship between factors associated with the COVID-19 pandemic and depression, anxiety, and stress (DAS) in dentists. Factors associated with the COVID-19 pandemic were evaluated using a questionnaire and scores of the Depression, Anxiety, and Stress Scales-21 were measured. The differences between the DAS scores based on the factors associated with the COVID-19 pandemic were tested through the successive application of multivariate analysis of variance (MANOVA, α = 0.05). After a sample size calculation, 998 participants with a mean age of 39.39 (± 11.69) years were included. The effect size indicated that changes in sleep quality (η2 = 0.161), eating habits (η2 = 0.057), and physical health (η2 = 0.051) were the ones that most negatively affected DAS scores. The highest DAS scores were observed in professionals who lived with someone at high-risk for COVID-19 (p < 0.001) and in those who did not engage in leisure activities during the pandemic (p < 0.001). Dentists who worked on the frontline against COVID-19 had higher scores of anxiety and stress (p = 0.029). The highest scores for anxiety, depression, and/or stress were seen in dentists living with someone at high-risk for COVID-19, who acts on the frontline, who does not practice in leisure activities during the pandemic, who completely changed eating habits, quality of sleep and physical health during the pandemic. In general, DAS levels of dentists were associated with factors related to the COVID-19 pandemic.


Asunto(s)
COVID-19 , Pandemias , Adulto , Ansiedad/epidemiología , Odontólogos , Depresión/epidemiología , Humanos , Persona de Mediana Edad , SARS-CoV-2
10.
Photodiagnosis Photodyn Ther ; 34: 102264, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33774192

RESUMEN

BACKGROUND: To evaluate the effects of three protocols for removing 0.01 % methylene blue from the post space after photodynamic therapy on bond strength and tag formation in the dentin of the fiber post space, using a conventional cementation system with an etch-and-rinse or universal adhesive system. METHODS: Sixty human canines were endodontically treated for fiber post cementation. The specimens were randomized into 6 groups (n = 10): G1, G2, G3, G4, G5, and G6. The G1, G2, and G3 groups were irrigated with saline solution, 2.5 % sodium hypochlorite (NaOCl), and 2.5 % NaOCl, agitated by passive ultrasonic irrigation (PUI), respectively. In these groups, a conventional cementation system with etch-and-rinse adhesive was used. The G4, G5, and G6 groups were irrigated with the respective solutions mentioned above and cemented using a conventional cementation system with universal adhesive. Tag formation in the dentin was evaluated by confocal laser scanning microscopy. The push-out bond strength test was performed on three thirds of the specimens. RESULTS: In the cervical and middle thirds, the greatest extent of dentin tag formation occurred in the G1 (p = 0.023 and p = 0.033, respectively). In the apical third, G1, G2, and G3 demonstrated similar tag formation between themselves (p = 0.089). In the cervical and middle thirds, G4 demonstrated the highest bond strength when compared to the other groups (p < 0.05). CONCLUSION: The protocols for removing 0.01 % methylene blue with NaOCl, irrespective of the involvement of passive ultrasonic irrigation, negatively effects the bond strength and tag formation in the dentin of the post space.


Asunto(s)
Cementación , Fotoquimioterapia , Animales , Dentina , Perros , Humanos , Ensayo de Materiales , Azul de Metileno , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes , Cementos de Resina
11.
J. health sci. (Londrina) ; 23(1): https://revista.pgsskroton.com/index.php/JHealthSci/article/view/7935, 20210330.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1179423

RESUMEN

The teeth weakening due to the preparation of class II mesio-occluso-distal cavities is a challenge for the clinician. The objective of this study was to evaluate the molars fracture resistance with class II mesio-occluso distal cavities restored with different restorative techniques and materials. Forty extracted molars were divided into 5 groups: Group 1 ­ intact healthy teeth (positive control); Group 2 ­ unrestored teeth with mesio-occluso distal class II cavities (negative control); Groups 3 to 5 ­ restored teeth with standardized dimensions. In groups 3 to 5, the cavities were restored with flow resin only, flow resin coated with a nano-hybrid resin, and nano-hybrid resin only, respectively. All specimens were tested for resistance to fracture using an axial compressive load, a metallic sphere measuring 8 mm in diameter on a universal testing machine EMIC DL-2000. A 10 kN load cell operated at a speed of 5 mm/min until the tooth fracture. Data were subjected to analysis of variance and Tukey's tests (α = 0.05). Group 3 showed higher fracture strength (2243.1 ± 473.7N) when compared to groups 2, 4 and 5. This difference was statistically significant (p<0.05). The fracture strength of teeth restored with flow mesio occluso-distal restorations was similar to that of intact natural teeth. (AU)


O enfraquecimento dos dentes devido às preparações de cavidades mesio-ocluso-distal é um desafio para o clínico. O objetivo deste estudo foi avaliar a resistência à fratura de molares com cavidades mesio-ocluso-distais classe II restauradas com diferentes técnicas e materiais restauradores. Quarenta molares extraídos foram divididos em 5 grupos: Grupo 1 ­ dentes saudáveis intactos (controle positivo); Grupo 2 ­ dentes não restaurados com cavidades mesio-occluso-distais classe II (controle negativo); Grupos 3 a 5 ­ dentes restaurados com dimensões padronizadas. Nos grupos 3 a 5, as cavidades foram restauradas apenas com resina flow, resina flow recoberta com uma resina nanohíbrida e somente resina nano-híbrida, respectivamente. Todas as amostras foram testadas quanto à resistência à fratura usando uma carga compressiva axial, usando uma esfera metálica medindo 8 mm de diâmetro em uma máquina de teste universal EMIC DL-2000. Uma célula de carga de 10 kN operava a uma velocidade de 5 mm/min até a fratura do dente. Os dados foram submetidos à análise de variância e testes de Tukey (α = 0,05). O grupo 3 apresentou maior resistência à fratura (2243,1 ± 473,7N) quando comparado aos grupos 2, 4 e 5. Essa diferença foi estatisticamente significante (p <0,05). A resistência à fratura dos dentes restaurados com resina flow foi semelhante à dos dentes naturais intactos. (AU)

12.
Int. j. odontostomatol. (Print) ; 14(1): 60-66, mar. 2020. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1056502

RESUMEN

ABSTRACT: The objective of the study was to evaluate marginal adaptation of Class II mesial-occlusal-distal (MOD) restorations before and after thermo-mechanical loading and volumetric shrinkage of the bulk-fill vs conventional composite resin. For marginal adaptation assessment, 24 Class II MOD cavities with cervical margins extending 1.0 mm below (distal) and 1.0 mm beyond (mesial) the cement-enamel junction were prepared in extracted human molars. The teeth were filled as follows: Group A - bulk-fill with SureFil SDR flow (first increment, 4 mm; second increment, 2 mm); Group B - bulk-fill with SureFil SDR flow as a base (first increment, 4 mm) and covered with the conventional nanohybrid composite Esthet-X HD (second increment, 2 mm); and Group C - incrementally filled with Esthet-X HD. Marginal adaptation was evaluated by scanning electron microscopy before and after thermomechanical loading (240,000 loading cycles and simultaneous 600 thermal cycles). To evaluate volumetric polymerization shrinkage, a semi-spherical mold was filled with the tested composites and placed in an AccuVol device after light curing. Both before and after loading, marginal adaptation in cervical dentin was superior (p < 0.05) for Groups A and B compared with Group C. In cervical enamel, Group B showed better marginal adaptation than Group C, and Group A presented intermediary results, between Groups B and C. Furthermore, bulk-fill flow resulted in greater shrinkage than Esthet-X HD. A significant improvement of marginal adaptation was observed when bulkfill flow was used instead of conventional composite resin both before and after thermomechanical loading. However, the bulk-fill flow presented higher volumetric polymerization shrinkage than the conventional composite.


RESUMEN: El objetivo de este trabajo consistió en evaluar la adaptación marginal de las restauraciones mesiales-oclusales-distales (MOD) de Clase II antes y después de la carga termo-mecánica y la contracción volumétrica de la carga compuesta de resina "bulk-fill" en comparación con resina convencional. Para la evaluación de adaptación, se prepararon 24 cavidades MOD de Clase II en molares humanos extraídos, los que se restauraron de la siguiente manera: Grupo A: restaurado con resina fluida Bulk-Fill SureFilSDR (primer incremento, 4 mm; segundo incremento, 2 mm); Grupo B: restaurado con resina fluida Bulk-Fill SureFil SDR (primer incremento, 4 mm) y cubierto con resina compuesta nanohíbrida Esthet-X HD (segundo incremento, 2 mm); y Grupo C - rellenado incrementalmente con Esthet-X HD. La adaptación marginal se evaluó mediante microscopía electrónica de barrido antes y después de la carga termomecánica (240.000 ciclos de carga y 600 ciclos térmicos simultáneos). Para evaluar la contracción volumétrica de la polimerización, se llenó un molde semiesférico con los compuestos probados y se colocó en un dispositivo AccuVol después del fotopolimerización. Tanto antes como después de la carga, la adaptación marginal en la dentina cervical fue superior (p <0,05) para los grupos A y B en comparación con el grupo C. En el esmalte cervical, el grupo B mostró una mejor adaptación marginal que el grupo C, y el grupo A presentó resultados intermedios, entre Grupos B y C. Se observó una mejora significativa de la adaptación marginal al utilizar la resina fluida Bulk-Fill en lugar de resina compuesta convencional tanto antes como después de la carga termomecánica. Sin embargo, la resina fluida 'Bulk-Fill' presentó una mayor contracción volumétrica de polimerización que el compuesto convencional.


Asunto(s)
Humanos , Adaptación Marginal Dental , Resinas Compuestas , Preparación de la Cavidad Dental/instrumentación , Restauración Dental Permanente/métodos , Maloclusión Clase II de Angle , Estrés Mecánico , Comités de Ética , Alisadura de la Restauración Dental , Preparación de la Cavidad Dental/normas , Polimerizacion
13.
Braz Oral Res ; 33: e026, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30970090

RESUMEN

The aim of this study is to evaluate the machinability of four CAD/CAM materials (n = 13) assessed by brittleness index, Vickers hardness, and fracture toughness and interaction among such mechanical properties. The materials selected in this in vitro study are Feldspathic ceramic [FC], Lithium-disilicate glass ceramic [LD], leucite-reinforced glass ceramic [LR], and nanofilled resin material [RN]. Slices were made from the blocks following original dimensions 14 × 12 × 3 mm (L × W × H), using a precision slow-speed saw device and then surfaces were regularized through a polishing device. Brittleness index and fracture toughness were calculated by the use of specific equations for each one of the properties. The Vickers hardness was calculated automated software in the microhardness device. One-way Anova and Pearson's correlation were applied to data evaluation. LD obtained the highest values for brittleness index and was not significantly different from FC. LR presented statistically significant difference compared with RN, which had the lowest mean. Vickers hardness showed LD with the highest average, and no statistical difference was found between FC and LR. RN presented the lowest average. Fracture toughness showed FC and LR not statistically different from each other, likewise LD and RN. The brittleness index, considered also as the machinability of a material, showed within this study as positively dependent on Vickers hardness, which leads to conclusion that hardness of ceramics is related to its milling capacity. In addition, fracture toughness of pre-sintered ceramics is compared to polymer-based materials.


Asunto(s)
Silicatos de Aluminio/química , Cerámica/química , Diseño Asistido por Computadora , Porcelana Dental/química , Polímeros/química , Cementos de Resina/química , Análisis de Varianza , Pruebas de Dureza , Ensayo de Materiales , Valores de Referencia , Reproducibilidad de los Resultados , Estadísticas no Paramétricas , Propiedades de Superficie
14.
Braz. oral res. (Online) ; 33: e026, 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1001604

RESUMEN

Abstract: The aim of this study is to evaluate the machinability of four CAD/CAM materials (n = 13) assessed by brittleness index, Vickers hardness, and fracture toughness and interaction among such mechanical properties. The materials selected in this in vitro study are Feldspathic ceramic [FC], Lithium-disilicate glass ceramic [LD], leucite-reinforced glass ceramic [LR], and nanofilled resin material [RN]. Slices were made from the blocks following original dimensions 14 × 12 × 3 mm (L × W × H), using a precision slow-speed saw device and then surfaces were regularized through a polishing device. Brittleness index and fracture toughness were calculated by the use of specific equations for each one of the properties. The Vickers hardness was calculated automated software in the microhardness device. One-way Anova and Pearson's correlation were applied to data evaluation. LD obtained the highest values for brittleness index and was not significantly different from FC. LR presented statistically significant difference compared with RN, which had the lowest mean. Vickers hardness showed LD with the highest average, and no statistical difference was found between FC and LR. RN presented the lowest average. Fracture toughness showed FC and LR not statistically different from each other, likewise LD and RN. The brittleness index, considered also as the machinability of a material, showed within this study as positively dependent on Vickers hardness, which leads to conclusion that hardness of ceramics is related to its milling capacity. In addition, fracture toughness of pre-sintered ceramics is compared to polymer-based materials.


Asunto(s)
Polímeros/química , Cerámica/química , Diseño Asistido por Computadora , Cementos de Resina/química , Porcelana Dental/química , Silicatos de Aluminio/química , Valores de Referencia , Propiedades de Superficie , Ensayo de Materiales , Reproducibilidad de los Resultados , Análisis de Varianza , Estadísticas no Paramétricas , Pruebas de Dureza
15.
Rev. odontol. UNESP (Online) ; 48: e20190007, 2019. tab
Artículo en Portugués | LILACS, BBO - Odontología | ID: biblio-991492

RESUMEN

Resumo Introdução Os adesivos autocondicionantes apresentam técnica adesiva simplificada e diminuição na sensibilidade pós-operatória. Quando aplicados sobre a dentina, atuam sobre a smear layer, cuja efetiva remoção ainda constitui um desafio. Uma substância utilizada como pré-tratamento dentinário na ajuda da remoção da smear layer é o etilenodiamino tetracético dissódico (EDTA). Objetivo Avaliar os efeitos do EDTA em associação com sistemas adesivos autocondicionantes na resistência de união ao microcisalhamento. Material e método Foram seccionadas as superfícies oclusais de 72 terceiros molares humanos extraídos, para expor superfície dentinária plana. Os dentes preparados foram divididos em: dentina sem pré-tratamento; dentina tratada com EDTA 0,1M; dentina tratada com EDTA 0,5M. Cada grupo recebeu tratamento de três sistemas adesivos autocondicionantes: Single Bond Universal (SBU), AdheSE (AdheSE) e Clearfil SE Bond (CSEB). Foi delimitada a área adesiva e assim posicionada uma matriz transparente, para inserção com resina composta Z250XT seguida de polimerização por 40 segundos. Após 24 horas de armazenamento, os dentes foram submetidos ao ensaio de microcisalhamento. Os dados obtidos foram analisados estatisticamente, utilizando-se os testes Two-Way ANOVA e Bonferroni, e sendo considerado nível de significância de 5%. Resultado Não houve diferença estatística significante na resistência de união entre os pré-tratamentos dentinários (p=0,8353), porém houve diferença significativa entre os adesivos (p<0,05) CSEB e AdheSE, mostrando semelhança entre CSEB e SBU, e entre SBU e AdheSE. Conclusão O pré-tratamento dentinário com solução de EDTA não afetou a resistência de união com nenhum dos sistemas adesivos autocondicionantes utilizados.


Abstract Introduction Self-etching adhesives have simplified adhesive technique and decreased the postoperative sensitivity. When applied on dentin, it acts on the smear layer, but it is still a challenge in the effectiveness of this removal. A substance used as a pre-treatment for the removal of the smear layer is disodium ethylenediaminetetraacetic acid (EDTA). Objective To evaluate the effects of EDTA in association with self-etching adhesive systems on micro-shear bond strength. Material and method The occlusal surfaces of 72 extracted human third molars were sectioned to expose a flat dentin surface. The prepared teeth were divided into: dentin without pre-treatment; dentin treated with 0.1M EDTA; dentin treated with 0.5M EDTA. Each group received treatment of 3 self-etching adhesive systems: Single Bond Universal (SBU), AdheSE (AdheSE), and Clearfil SE Bond (CSEB). The adhesive area was delimited and positioned a transparent matrix for insertion with Z250XT composite resin followed by polymerization for 40 seconds. After 24h of storage, the teeth were submitted to the micro-shear test. The data were analyzed statistically using the Two-Way ANOVA and Bonferroni tests, considering a level of significance of 5%. Result There was no statistically significant difference in bond strength between dentin pre-treatments (p = 0.8353), but showed a significant difference between CSEB and AdheSE adhesives (p <0.05), showing similarity between CSEB and SBU, and between SBU and AdheSE. Conclusion Dentin pretreatment with EDTA solution did not affect bond strength with any of the self-etching adhesive systems used.


Asunto(s)
Adhesivos , Resultado del Tratamiento , Ácido Edético , Dentina , Hipoclorito de Sodio , Eficacia , Resistencia al Corte , Sensibilidad de la Dentina , Polimerizacion
16.
Am J Dent ; 31(4): 205-210, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30106537

RESUMEN

PURPOSE: To compare the fracture toughness of four different CAD/CAM materials, (VM) Vitablocs Mark II, (IP) IPS e.max CAD, (LU) LAVA Ultimate, and (VE) Vita Enamic under long thermocycling conditions. METHODS: Each type of ceramic block was sectioned into beams (n=9) with dimensions of 14×3×2.5 mm (L × W × H). All four ceramics were submitted to different conditions: the desiccator or distilled water, each for 7 days. The third and fourth conditions involved the specimens being submitted to 60,000 and 120,000 thermocycles in water respectively. The dwelling time was 52 seconds at 5° and 55°C. A three-point bend test with a universal loading machine on notched samples was per-formed. Furthermore, a fractographic analyses was made by scanning electron microscopy (SEM) to determine if any of these conditions influenced the type of fracture. Data were analyzed by two-way ANOVA (α= 0.05). RESULTS: A significant difference in fracture toughness (P< 0.05) was found among the groups; IP (4.20±1.23) had the highest value followed by VE (2.02±0.39), which did not have a statistically significant difference from LU (1.96±0.42). The lower value and statistical difference for VM was 1.52±0.35. The ceramics performed better after they were hydrated, while the polymer-based materials had the fracture toughness means decreased after the thermocycles. CLINICAL SIGNIFICANCE: A significant difference in fracture toughness (P<0.05) was found among the groups; IP had the highest value followed by VE, which was not statistically significantly different from LU. The ceramics performed better after they were hydrated, while the polymer-based materials had fracture toughness means decreased after thermocycling.


Asunto(s)
Diseño Asistido por Computadora , Porcelana Dental , Cerámica , Ensayo de Materiales
17.
Rev. odontol. UNESP (Online) ; 46(3): 131-137, May-June 2017. tab, ilus
Artículo en Portugués | LILACS, BBO - Odontología | ID: biblio-902652

RESUMEN

Introdução: A evolução dos sistemas adesivos permitiu que os fabricantes desenvolvessem materiais com técnicas cada vez mais simplificadas, porém que, ainda assim, promovessem adequados valores de resistência de união imediata. Sugere-se que alguns tratamentos da superfície dentinária podem favorecer esse processo de adesão. Objetivo: Avaliar os efeitos de diferentes tratamentos, em superfície dentinária plana condicionada, sobre a resistência de união à microtração de sistemas adesivos do tipo "condiciona-e-lava" de dois passos. Material e método: Noventa e seis terceiros molares humanos foram divididos em 12 grupos (n=8), aleatoriamente, de acordo com o sistema adesivo utilizado (GI: Adper Single Bond 2 - 3M ESPE; GII: Prime & Bond 2.1 - Dentsply; GIII: Excite - Ivoclar Vivadent) e o tipo de tratamento do substrato dentinário condicionado (a: água; b: clorexidina + água; c: etanol; d: clorexidina + etanol). Todos os dentes foram restaurados com resina Charisma na cor A2 (Heraeus - Kulzer, Germany) e submetidos a ensaio mecânico de microtração (EMIC DL-2000). O teste estatístico realizado foi ANOVA a um fator, completado com teste de Tukey. Resultado: Os grupos GIIc, GIIIc e GIId apresentaram aumento significativo estatisticamente na resistência de união à microtração imediata. Conclusão: Os diferentes tratamentos da dentina condicionada não afetaram de maneira negativa a resistência de união para todos os sistemas adesivos testados e a utilização da técnica com etanol, associado ou não à clorexidina, parece ser uma interessante abordagem quando associada a sistemas adesivos "condiciona-e-lava" de dois passos.


Introduction: The development of adhesive systems allow manufacturers to develop materials with increasingly simplified techniques, but that still would promote adequate resistance values of immediate union. It is suggested that some treatments of dentin surface can facilitate the process of accession. Objective: To evaluate the effects of different treatments in conditioned flat dentin surface on bond strength to microtensile 2-step etch-and-rinse adhesive systems. Material and method: Ninety-six human third molars were divided into twelve groups (n = 8) randomly according to the used adhesive system (GI: Single Bond 2 - 3M ESPE; GII: Prime & Bond 2.1 - Dentsply; GIII: Excite - Ivoclar Vivadent) and type of treatment of the conditioned dentin (a: water; b: water + chlorhexidine; c: ethanol; d: chlorhexidine + ethanol). All teeth were restored with Charisma color A2 (Heraeus - Kulzer, Germany) and subjected to mechanical testing microtensile (EMIC DL-2000). The statistical test performed was ANOVA 1 factor supplemented with Tukey test. Result: GIIc groups GIIIc and GIId showed statistically significant increase in bond strength to immediate microtensile. Conclusion: The different treatments of dentin did not affect negatively the bond strength for all tested adhesive systems and the use of the technique with ethanol, with or without chlorhexidine, appears to be an interesting approach when combined with 2-step etch-and-rinse adhesive systems.


Asunto(s)
Clorhexidina , Recubrimientos Dentinarios , Resistencia al Corte , Dentina , Etanol , Diente Molar , Análisis de Varianza
18.
RSBO (Impr.) ; 12(2): 143-150, Apr.-Jun. 2015. ilus, tab
Artículo en Inglés | LILACS | ID: lil-792036

RESUMEN

Introduction: Most of techniques for determining the occlusal vertical dimension (OVD) of edentulous patients are based on soft tissues references, which lead to measurement discrepancies. Objective: To propose a method to obtain the OVD of edentulous patients during the confection of complete dentures considering the lower facial height established by Ricketts (LFHr) or the lower facial height obtained from cephalometric analysis of dentulous patients (LFHd). Material and methods: The OVD of 11 edentulous patients was determined by the association of 3 clinical methods. On each patient's bite plates a metallic ball was fixed and the patient was submitted to lateral radiographic to obtain the lower facial height (LFHe) from cephalometric analysis. Additionally, from 40 lateral cephalograms of dentulous patients the LFHd was obtained. After that, the distance between metallic balls (DMB, in mm) was calculated to verify the linear difference when LFHe was changed to LFHd or LFHr, which provided the amount of wax to be added or removed from the bite plates, establishing a new method of OVD determination. LFHe, LFHd and LFHr values were submitted to t e z statistical tests and DMB differences were analyzed by Student's t-test (α=0.05). Results: LFHr (47.0±4.0o a) was statistically higher than LFHd (44.9±5.6o b) and LFHe (43.5±3.5o b). There was statistical difference on linear discrepancies calculated between the LFHe and LFHd (1.7±4.1mm a) or LFHr (4.2±4.1mm b). Conclusion: The use of the cephalometric analysis showed to be a useful auxiliary tool in determining the intermaxillary relationship. However, this method must be associated with different clinical methods of OVD determination and it is recommended that regional references are used to calculate the linear discrepancies.

19.
J Contemp Dent Pract ; 15(2): 186-9, 2014 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-25095841

RESUMEN

AIM: The aim of this study was to evaluate the fracture resistance of teeth submitted to several internal bleaching protocols using 35% hydrogen peroxide (35HP), 37% carbamide peroxide (37CP), 15% hydrogen peroxide with titanium dioxide nanoparticles (15HPTiO2) photoactivated by LED-laser or sodium perborate (SP). MATERIALS AND METHODS: After endodontic treatment, fifty bovine extracted teeth were divided into five groups (n = 10): G1-unbleached; G2-35HP; G3-37CP; G4-15HPTiO2 photoactivated by LED-laser and G5-SP. In the G2 and G4, the bleaching protocol was applied in 4 sessions, with 7 days intervals between each session. In the G3 and G5, the materials were kept in the pulp teeth for 21 days, but replaced every 7 days. After 21 days, the teeth were subjected to compressive load at a cross head speed of 0.5 mm/min, applied at 135° to the long axis of the root using an eletromechanical testing machine, until teeth fracture. The data were submitted to ANOVA and Tukey tests (α = 5%). RESULTS: The 35HP, 37CP, 15HPTiO2 and SP showed similar fracture resistance teeth reduction (p > 0.05). All bleaching treatments reduced the fracture resistance compared to unbleached teeth (p < 0.05). CONCLUSION: All bleaching protocols reduced the fracture resistance of endodontically-treated teeth, but there were no differences between each other. CLINICAL SIGNIFICANCE: There are several internal bleaching protocols using hydrogen peroxide in different concentrations and activation methods. This study evaluated its effects on fracture resistance in endodontically-treated teeth.


Asunto(s)
Cavidad Pulpar/efectos de los fármacos , Blanqueadores Dentales/uso terapéutico , Blanqueamiento de Dientes/métodos , Fracturas de los Dientes/fisiopatología , Animales , Boratos/uso terapéutico , Peróxido de Carbamida , Bovinos , Análisis del Estrés Dental/instrumentación , Peróxido de Hidrógeno/uso terapéutico , Terapia por Luz de Baja Intensidad , Ensayo de Materiales , Nanopartículas , Peróxidos/uso terapéutico , Fármacos Fotosensibilizantes/uso terapéutico , Distribución Aleatoria , Tratamiento del Conducto Radicular/métodos , Estrés Mecánico , Factores de Tiempo , Titanio/uso terapéutico , Urea/análogos & derivados , Urea/uso terapéutico
20.
RSBO (Impr.) ; 11(2): 192-198, Apr.-Jun. 2014.
Artículo en Inglés | LILACS | ID: lil-778280

RESUMEN

Introduction: The alveolar bone resorption that occurs after tooth loss leads to maladaptation of prostheses over the mucosa, causing discomfort to the patient. However, these maladaptations can be solved by prosthesis relining. Objective: The aim of this study was to discuss based on the literature, the relining of complete and partial removable dentures. Literature review: Dentistry makes use of relining materials that can be either rigid or resilient, having a temporary or permanent characteristic. However, to obtain a satisfactory result, the knowledge of their indications, contraindications, advantages, disadvantages is required, in addition to the characteristics and types of materials. Patients should be aware of the importance of constant monitoring, or even the need to reline their dentures, as it is not possible to determine the biological tolerance of each individual. Conclusion: The installation and proservation phases become essential to minimize bone resorption, and also to achieve rehabilitative treatment success.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...